  Abstract 

Background: Naproxen sodium (NAP) is a non steroidal anti-inflammatory drug and Esomeprazole magnesium trihydrate (ESO) is a proton pump inhibitor. Aim: A high performance liquid chromatographic method was developed and validated for the quantitative determination of naproxen (NAP) sodium and esomeprazole (ESO) magnesium trihydrate. The different analytical parameters such as linearity, precision, accuracy, limit of detection and limit of quantification were determined according to the International conference harmonization (ICH) Q2B guidelines. Materials: Chromatography was carried out by isocratic technique on a reversed phase C18 base deactivated silanol hypersil column with mobile phase and optimized depending upon the polarity of the molecules. Results: The calibration curves were linear (r2 > 0.9997) over the concentrations 20-120 μg/mL for NAP sodium and 0.8-4.8 μg/mL for ESO magnesium trihydrate. The method was accurate and precise with recoveries in the range of 99.48-99.98% for the two drugs and relative standard deviation less than 2%. No chromatographic interferences from the tablet excipients were found. Conclusion: The proposed method was highly sensitive, precise and accurate. Hence the method was successfully applied for the reliable quantification of active pharmaceutical ingredients content in house prepared tablet formulation of NAP sodium and EOS magnesium trihydrate.

Keywords: Esomeprazole magnesium trihydrate, naproxen sodium, reverse phase-high performance liquid chromatography, validation, % relative standard deviation


How to cite this article:
Saravanan S, Sudha T, Surendra B. Development and validation of reverse phase-high performance liquid chromatographic method for simultaneous estimation of naproxen sodium and esomeprazole magnesium trihydrate. Drug Dev Ther 2014;5:109-14

How to cite this URL:
Saravanan S, Sudha T, Surendra B. Development and validation of reverse phase-high performance liquid chromatographic method for simultaneous estimation of naproxen sodium and esomeprazole magnesium trihydrate. Drug Dev Ther [serial online] 2014 [cited 2017 Jun 24];5:109-14. Available from: http://www.ddtjournal.org/text.asp?2014/5/2/109/139614


  Introduction Top


Naproxen (NAP) sodium [Figure 1]a is a non steroidal anti-inflammatory drug, whose action has been inhibition of cyclooxygenase (COX-1). It is thought to be associated with gastrointestinal and renal toxicity while inhibition of COX-2 provides anti-inflammatory activity. [1] Esomeprazole (ESO) magnesium trihydrate [Figure 1]b is a proton pump inhibitor that suppresses gastric acid secretion by specific inhibition on the H + /K + -ATPase in the gastric parietal cell.
Figure 1: (a) Structure of naproxen sodium, (b) structure of esomeprazole magnesium

Click here to view


The S and R isomers of omeprazole are protonated and converted in the acidic compartment of the parietal cell forming the active inhibitor, the achiral sulphonamide. By acting specifically on the proton pump, ESO blocks the final step in production, thus reducing gastric activity. NAP sodium is chemically known as 2-naphthalene acetic acid, 6-methoxy-α-methyl-sodium salt and ESO magnesium trihydrate is chemically known as 5-methoxy-2 -([S]-[(4 methoxy-3, 5-dimethyl-2-pyridyl)] methyl) sulfinyl benzimidazole, magnesium salt trihydrate. [2]

A literature survey reveals that there are a number of various analytical methods available for the quantitative individual determination of NAP sodium or combination with other drugs mainly using chromatographic methods such as liquid chromatography with different columns. [3],[4],[5],[6],[7],[8],[9] Although several high performance liquid chromatographic (HPLC) methods have been published for this combination of drugs [10],[11],[12] , a trial has been made to evaluate the same combination which could be a better method with less retention time, less percentage degradation and a cost effective mobile phase. Hence an attempt has been made to develop a simple, efficient and selective method for the determination of NAP and ESO. In this study, HPLC instrumentation with ultra violet (UV) detection which is readily available in most analytical and pharmaceutical laboratories was used.


  Experimental Top


Chemicals

The bulk drugs of NAP and ESO were obtained as gift samples from Chandra labs, Hyderabad. HPLC grade water and Acetonitrile were obtained from Rankem. Analytical grade potassium dihydrogen phosphate and dipotassium hydrogen phosphate were obtained from Fluka laboratories, Mumbai. Excipients such as polydextrose, propylene glycol, magnesium stearate, polysorbate 80 and starch were obtained from Ankit enterprises, Mumbai.

Instrumentation and analytical conditions

Chromatography was performed by using a Shimadzu liquid chromatographic HPLC system equipped with reciprocating plunger pump LC-20, manual injector and UV-detector. Data acquisition and processing were performed using spinchrom software. Separation was achieved on C 18 column, base deactivated silanol Hypersil with a length of 250 mm, 4.6 inner diameter and pore size of 5 μ. The elution was isocratic with mobile phase of mixed phosphate buffer adjusted to pH 6.8 with ortho phosphoric acid and acetonitrile (55:45 v/v). The flow rate was 1.0 mL/min. Column temperature was maintained at ambient; the detection was monitored at a wavelength of 236 nm and injection volume was 20 μL.

Standard solution and calibration graphs for chromatographic measurements

Standard stock solution was prepared by dissolving 50 mg of NAP and 2 mg of ESO in the mobile phase to obtain concentration of 1000 μg/mL and 40 μg/mL respectively. Further dilutions with the mobile phase were done to obtain the working standard concentration in the range of 20 μg/mL to 120 μg/mL and 0.8 μg/mL to 4.8 μg/mL respectively. Quality control samples were prepared in the range of calibration curves at different concentrations (70, 90, 110 μg/mL NAP and 2.8, 3.6, 4.4 μg/mL for ESO) following the same procedure as for the calibration standard using a primary stock. The samples were analyzed with the reagent blank. All the solutions were prepared in triplicate.


  Method Validation Top


The method was validated according to the international conference harmonization (ICH) Q2B guidelines. [13] The following validation characteristics were addressed for linearity, accuracy, precision, specificity, limit of detection (LOD), limit of quantification (LOQ) and robustness.

Linearity and range

Standard calibration curves were prepared with six calibrators over a concentration range of 20 μg/mL to 120 μg/mL for NAP and 0.8 μg/mL to 4.8 μg/mL for ESO. The data of peak areas versus concentrations were treated by linear least square regression analysis.

Accuracy

To study the reliability and suitability of the developed method, recovery experiments were carried out. Accuracy is the percent of analysis recovered by among from a known added amount. Data from the nine determinations over time (70, 90, 110 μg/mL NAP and 2.8, 3.6, 4.4, μg/mL for ESO) concentration levels covering the specified ranges were determined.

Precision

Precision is the degree of repeatability of an analytical method under normal conditions. Repeatability and method precision were done to the precision of the method. Aliquots of standard stock solutions of NAP and ESO (1 mL of 1000 μg/mL for NAP and 1 mL of 40 μg/mL for ESO) were transferred into a 10 mL standard flask and made up to the mark with mobile phase (100 μg/mL for NAP and 4.0 μg/mL for ESO). 20 μL of the solution was injected and the chromatograms were recorded. The procedures were repeated for 5 times. The peak areas were measured and the % relative standard deviation was calculated.

LOD and LOQ

The LOD is defined as the lowest concentrations of an analytical process can reliably differentiate from background levels. The LOQ is defined as the lowest concentrations of the standard curve that can be measured with acceptable accuracy, precision and variability. The LOD and LOQ were calculated as



Where σ - is the standard deviation of the lowest standard concentration and 's' is the slope of the standard curve.

Specificity

Forced degradation studies were performed to provide an indication of the stability indicating properties and specificity of the method. The degradation samples were prepared by transferring from standard stock (1 mL of 1000 μg/mL for NAP and 1 mL of 40 μg/mL for ESO) into 10 mL volumetric flasks. International degradation was attempted using heat, acid and base. After the degradation treatments were completed, the samples were allowed to equilibrate to room temperature and prepared according to precision preparation. The samples were analyzed against a freshly prepared control sample (with no degradation treatment). Degradation peaks were observed, were resolved from the active peak and did not reveal any degradation products coeluting with the active peak.

Robustness

As a part of robustness deliberate change in flow rate (0.9 mL/min and 1.1 mL/min) and wavelength (234 nm and 238 nm) were made to elevate the impact of the method.

Formulation and standard test

At the time of my doing this research work, the tablet formulations of NAP and ESO combination were not available in Indian market and it was only available in USA market. Hence 40 tablets of NAP and ESO combination were prepared in the laboratory with the help of excipients by direct compression method.

Direct compression method

Required quantity of polysorbate 80 and propylene glycol were weighed and triturated. Then weighed quantity of drugs were added and mixed well. Polydextrose was added and then the required quantities of starch and magnesium stearate were mixed. The powder was punched by using single punching machine.

Extraction of active ingredients

The tablets were accurately weighed and powdered. The amount of the drug in weighed quantity of powder was calculated based on the label claim and the active ingredients were extracted in the mobile phase. The solution was sonicated for 20 min and filtered through Whatmann No: 41 filter paper. Appropriate dilutions were made and the samples were subjected for HPLC analysis.


  Results and Discussion Top


Method development

Method development focuses on identifying buffer type, strength and pH organic solvent and implementing small changes to optimize selectivity and enhance resolution. Initially, the efficiency was found to be 636 and 1718 for NAP sodium and ESO magnesium trihydrate by using the stationary phase with YMC C 18 short column with mobile phase containing water: Acetonitrile in the ratio of 50:50 v/v with flow rate 1.0 mL/min. To increase the efficiency for NAP and ESO by using stationary phase YMC C 18 short column with mobile phase containing mixed phosphate buffer adjusted to pH 6.8 and acetonitrile in the ratio of 55:45 v/v with flow rate of 1.0 mL/min but the resolution was found to be 1.790 min. Then tried with YMC C 18 short column with mobile phase containing ammonium phosphate buffer and acetonitrile in the ratio of 60:40 v/v with flow rate of 1.5 mL/min but the efficiency was found to be 674 and 823 for NAP and ESO respectively. At this stage the stationary phase BDS Hypersil C 18 long column and with mobile phase containing mixed phosphate buffer adjusted to pH 6.8 and acetonitrile in the ratio of 70:30 v/v with flow rate of 1.5 mL/min. The retention time of NAP and ESO were found to be 7.907 min. and 14.030 min. respectively. To reduce the retention time by using the same stationary phase and mobile phase containing water: Methanol 50:50 v/v with flow rate of 1.5 mL/min. The retention time of NAP was found to be 2.593 min. However, the retention time of ESO was found to be 14.803 min. Again to reduce the retention time of ESO by using the same stationary phase with mobile containing mixed phosphate buffer adjusted to pH 6.8 and Acetonitrile in the ratio of 55:45 v/v with flow rate of 1.0 mL/min. The retention time was found to be 3.137 min. and 4.340 min. for NAP and ESO respectively.

Using the above chromatographic conditions resulted in the development of an efficient and reproducible method for the quantitative determination of NAP and ESO in bulk and tablet dosage form. In-vitro quality control tests such as friability, uniformity of weight, hardness, dissolution, disintegration and assay were performed. Quality control tests for the tablets results are shown in [Table 1]. The optimized chromatogram is shown in [Figure 2] and the method development trials results are shown in [Table 2].
Figure 2: Optimized chromatogram

Click here to view
Table 1: Quality control tests for formulation

Click here to view
Table 2: Method development trails

Click here to view


Method validation

When a method has been developed, it must be validated before practical use. By following the ICH guidelines for analytical method validation Q 2 (R 1 ), the system suitability test was performed and the validation characteristics were addressed.

System suitability

The system suitability test ensures the validity of the analytical procedure as well as confirms the resolution between different peaks of interest. System suitability parameters such as retention time, tailing factor, efficiency, capacity factor and resolution were performed. The results were found to be within the United States Pharmacopeia [14] limits and the reports of analysis are shown in [Table 3].
Table 3: System suitability parameters

Click here to view


Linearity and range

For the construction of calibration curves, six calibration standard solutions were prepared over the concentration range from 20 μg/mL to 120 μg/mL for NAP and 0.8 μg/mL to 4.8 μg/mL for ESO. The results are summarized in [Table 4], shows a good correlation between analytes peak area and concentration with r2 > 0.9997 (n = 6). The calibration curves are shown in [Figure 3]a and b.
Figure 3: (a) Linearity curve of naproxen sodium, (b) linearity curve of esomeprazole magnesium

Click here to view
Table 4: Linearity

Click here to view


Accuracy

The accuracy of the method was confirmed by the recovery studies. To the pre analyzed formulation a different concentrations (70, 90, 110 μg/mL for NAP and 2.8, 3.6, 4.4 μg/mL for ESO) of the raw material were added and the amount of drug recovered was calculated. The percentage recovery was found to be 99.94, 99.98, 99.97% for NAP and 99.51, 99.53, 99.48 % for ESO respectively. The data is shown in [Table 5].
Table 5: Accuracy

Click here to view


Precision and intermediate precision

The standard NAP and ESO solution of 100 μg/mL and 4 μg/mL were selected for analysis. The % RSD values for precision were found to be 0.25 and 0.11 for NAP and ESO respectively. The % RSD [15] values for intermediate precision were found to be 0.76 and 0.21 for NAP and ESO respectively. The low % RSD values (not more than 2%) showed that the proposed method was precise. The results are shown in [Table 6]a and b.
Table 6:

Click here to view


Robustness

Robustness was performed by changing the flow rate and by changing the wavelength. It showed that there was no change in the values even after making deliberate changes in the analytical procedure. The results are shown in the [Table 7].
Table 7: Robustness

Click here to view


Specificity

Specificity was performed by treating the standard (NAP and ESO) with acid, base and heat. 20 μl of each treated standard was injected into the chromatographic system and recorded the degradation peaks. Degradation product should not interfere with the analytes and there was no change in the retention time. The % degradation was calculated by using peak area. It was found to be within the limit (Not more than 10%). Hence the method was found to be specific. The results were shown in [Table 8]. The chromatograms are shown in [Figure 4] a-c.
Figure 4: (a) Chromatogram for specificity (heating), (b) chromatogram for specificity (acid), (c) chromatogram for specificity (base)

Click here to view
Table 8: Specificity

Click here to view



  Conclusion Top


The HPLC method developed for NAP and ESO shows good precision and accuracy. The low % RSD values in the recovery studies for the method shows that there are no interferences due to excipients and for formulation. Hence it is concluded that the developed method is simple, precise and rapid for the analysis of combination of NAP and ESO in pure and in inhouse prepared tablet dosage form. Hence the developed method can be adopted for the routine analysis of combination of NAP and ESO in pure and in house prepared tablet dosage form.

 
  References Top

1.Pocock Nicola. "MHRA approves availability of OTC naproxen (Feminax ultra)". NHS Press Release.2006. http://www.bayer.ca/files/Aleve%20Release.July14.FINAL_.pdf  Back to cited text no. 1
    
2.Esomeprazole magnesium The American Society of Health-System Pharmacists. Retrieved 3 April 2011.   Back to cited text no. 2
    
3.Kumar R, Singh P, Singh H. Development and validation of RP-HPLC method for simultaneous estimation of naproxen and pantoprazole in pharmaceutical dosage form. Int J Pharma Res Dev 2011;2:227-32.  Back to cited text no. 3
    
4.Mondal S Haque A. Development and validation of RP-HPLC method for the simultaneous estimation of domperidone and naproxen in tablet dosage form. J Appl Pharm Sci 2011;7:145-8.  Back to cited text no. 4
    
5.Blagbrough IS, Daykin MM, Doherty M, Pattrick M, Shaw PN. High-performance liquid chromatographic determination of naproxen, ibuprofen and diclofenac in plasma and synovial fluid in man. J Chromatogr 1992;578:251-7.  Back to cited text no. 5
    
6.Onal A. Development and validation of high performance liquid chromatographic method for the determination of esomeprazole in tablets. J Food Drug Anal 2006;14:12-8.  Back to cited text no. 6
    
7.Dinç E, Ozdemir A, Aksoy H, Ustündað O, Baleanu D. Chemometric determination of naproxen sodium and pseudoephedrine hydrochloride in tablets by HPLC. Chem Pharm Bull (Tokyo) 2006;54:415-21.  Back to cited text no. 7
    
8.Kumar P, Shyale S. Physico-chemical characterization, UV spectrophotometric method development and validation studies of esomeprazole magnesium trihydrate. J Chem Pharm Res 2010;2:484-90.  Back to cited text no. 8
    
9.Trivedi PD, Maheswari DG. Estimation of esomeprazole and domperidone by absorption ratio method in pharmaceutical dosage forms. Int J Chem.Tech Res 2010;2:1598-605.  Back to cited text no. 9
    
10.Chandrakant S, Rajput S. Development and validation of RP-HPLC methods for simultaneous estimation of naproxen and esomeprazole magnesium trihydrate in combined pharmaceutical formulation. Int J Pharmacy Pharm. Sci 2012;4:533-7.  Back to cited text no. 10
    
11.Jain DK, Jain N, Charde R, Jain N. The RP-HPLC method for simultaneous estimation of esomeprazole and naproxen in binary combination. Pharm Methods 2011;2:167-72.  Back to cited text no. 11
[PUBMED]  Medknow Journal  
12.Reddy PS, Sait S, Vasudevmurthy G, Vishwanath B, Prasad V, Reddy SJ. Stability indicating simultaneous estimation of assay method naproxen and esomeprazole in pharmaceutical formulation by RP-HPLC. Der pharma chemica 2011;3:553-64.  Back to cited text no. 12
    
13.ICH Harmonized Tripartite Guidelines, Text on Validation of Analytical Procedures and Methodology Q2B. Geneva: p. 1-5.  Back to cited text no. 13
    
14.United States Pharmacopeia. Rock Ville, MD: United States of Pharmacopoeial Convention, Inc., 1995. p. 1061-963, 1988, 1990.  Back to cited text no. 14
    
15.Sethi PD. Quantitative Analysis of Drugs in Pharmaceutical Formulations. 3 rd ed. New Delhi: CBS Publishers and Distributors;2003. p. 6-9  Back to cited text no. 15
    


    Figures

  [Figure 1], [Figure 2], [Figure 3], [Figure 4]
 
 
    Tables

  [Table 1], [Table 2], [Table 3], [Table 4], [Table 5], [Table 6], [Table 7], [Table 8]



 

Top
 
 
  Search
 
Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
Access Statistics
Email Alert *
Add to My List *
* Registration required (free)

 
  In this article
Abstract
Introduction
Experimental
Method Validation
Results and Disc...
Conclusion
References
Article Figures
Article Tables

 Article Access Statistics
    Viewed1466    
    Printed52    
    Emailed0    
    PDF Downloaded230    
    Comments [Add]    

Recommend this journal


[TAG2]
[TAG3]
[TAG4]